Document:
The Liocrebif LKF-MXT50 is an industrial-grade 3-axis MEMS accelerometer with digital output and user-selectable measurement ranges of ±2g, ±4g, and ±8g. Designed for high-precision measurement systems, the MXT50 delivers low noise, low temperature drift, and excellent long-term stability. It is housed in a ceramic package that further enhances its long-term stability and reliability.
Liocrebif is a high-tech enterprise with fully closed-loop capabilities spanning fiber winding equipment and coils, FOGs, fiber/quartz three-axis MEMS accelerometer inertial products, IMU circuits, software, and test equipment. This end-to-end process control improves quality and reduces costs. Operating under ISO9001 with strict processes, Liocrebif ensures product reliability and consistency.
| Parameter | Condition | Min. | Typ. | Max. |
|---|---|---|---|---|
| Measurement Range (g) | User-selectable | — | 40 | — |
| -3dB Bandwidth (Hz) | — | — | 200 | — |
| Nonlinearity (%FS) | ±40g range | — | 0.3 | — |
| Cross-Axis Sensitivity (%) | — | — | 1 | — |
| Scale Factor (Sensitivity) (LSB/g) | ±40g range | — | 12800 | — |
| Sensitivity Temp Drift (%/℃) | 1σ, -40~85°C | — | ±0.01 | — |
| Sensitivity Repeatability (%) | 1σ, @25°C | — | 0.05 | — |
| Bias Output (mg) | X/Y/Z axis | — | ±2 | — |
| Bias Temp Drift (mg/℃) | -40°C ~ +85°C | — | ±3 | — |
| Bias Repeatability (mg) | X&Y / Z axis | — | ±1.5 / ±3 | — |
| VRE (g) | ±40g, 1g dir, 2.5g rms vibe | — | 20 | — |
| Bias Instability (ug, Allan) | X&Y / Z axis | — | 15 | — |
| Noise Density (ug/√Hz) | — | — | 90 | — |
| Velocity Random Walk (mm/s/√Hr) | X&Y / Z axis | — | 40 | — |
| Self-Test Output Change (g) | X&Y / Z axis | — | 0.5 | 1 |
| Output Data Rate (kHz) | — | — | 4 | — |
| Output Resolution (Bits) | — | — | 20 | — |
| Start-Up Time (ms) | Standby to Measure | — | 100 | — |
| Temp Sensor 25°C (T25) / Scale (TSF) | — | — | 5017.6 / 133.8 | — |
| Supply VCC (V) | — | 3.0 | 3.3 | 3.6 |
| IO Voltage VIO (V) | — | 1.8 | — | VCC |
| Digital/Analog GND (AVSS, DVSS) | — | — | 0 | — |
| Current Consumption (uA) | Measure / Standby | — | 600 / 20 | — |
| Operating Temp (℃) | — | -40 | — | +85 |
| Storage Temp (℃) | — | -50 | — | +125 |
| Humidity | — | — | — | 85% RH |
| Shock, unpowered (g) | 0.5 ms, 1/2 sine | — | — | 3,000 |
| Shock, powered (g) | 0.5 ms, 1/2 sine | — | — | 3,000 |
| ESD — HBM (kV) | — | 2 | — | — |
| ESD — CDM (V) | — | 500 | — | — |
Note: Exceeding the maximum ratings may affect product reliability and may cause permanent damage.
Send your inquiry directly to us